  • J-Type Compensating Cable 2x0.75 mm² – 100-Meter Roll
  • J-Type Compensating Cable 2x0.75 mm² – 100-Meter Roll

ThermoKoTec J-Type Compensating Cable 2x0.75 mm² – 100-Meter Roll

Product code : J-SCB-2-0,75-Ç-100K
Product Barcode : 791042503597
★
★
★
★
★
0 evaluation | Question & Answer Add to Favourites
50,351.98 TL   25,175.99 TL  
Free shipping
Color : Black - White

J-Type (Fe-Const) Compensating Cable 2x0.75 mm² – 100-Meter Roll

J-Type (Fe-Const) compensating cable 2x0.75 mm² is an industrial measurement cable used to maintain the connection between the J-Type thermocouple sensor and the temperature measuring instrument or controller. It helps carry the thermoelectric signal received from the sensor to the temperature controller, indicator, data logger, PLC thermocouple input or control panel.

The product combines a silicone- and fiberglass-based insulation structure with a steel braid on the outside. This construction is prepared for use in fixed sensor, machine and panel connections where temperature effects and superficial mechanical stress are present.

The two-core structure with nominal cross-section 2x0.75 mm² can be used in J-Type thermocouple measurement circuits with suitable terminals and connectors. The product is supplied as a single 100-meter roll and can be cut to the lengths required for production, maintenance, control-panel assembly, and field applications.

This product is not a standard power supply cable. It should be used in J-Type thermocouple measurement circuits. It must be verified that the sensor type, compensating cable, connection elements and measuring instrument input are compatible with each other.

Silicone, Fiberglass, and Steel-Braid Construction

The product uses silicone + fiberglass + steel braid for its insulation and protective construction. The silicone and fiberglass layers help keep the cable cores electrically separated and protect the cable body.

Silicone-based insulation can be preferred in sensor and panel connections that require flexibility. The fiberglass structure supports the cable body in fixed industrial connections where temperature effects are present.

The outer steel braid creates an auxiliary layer of mechanical protection around the cable. It contributes to the protection of the cable against friction and light mechanical effects in routes with machine body, panel passage, cable duct and surface contact.

The main function of the steel braid is mechanical protection. If it is planned to be used as an electrical shield, the electrical continuity of the braid, coverage structure, connection method and device manufacturer's instructions should also be evaluated.

Technical Specifications

  • Product type: Compensating cable
  • Compatible measurement circuit: J-Type thermocouple
  • Thermocouple definition: J-Type (Fe-Const)
  • Number of cores: 2 cores
  • Core / cross-sectional area: 2x0.75 mm²
  • Insulation structure: Silicone + fiberglass
  • External protection: Steel braid
  • Sales method: 100-meter roll
  • Product code: J-SCB-2-0,75-Ç-100K
  • Product barcode: 791042503597

Fe-Const and J-Type Measurement Compatibility

The expression Fe-Const refers to the thermoelement pair used in J-Type thermocouple systems. Fe refers to the iron conductor and Const refers to the thermoelement alloy called Constantan.

When choosing a compensating cable, not only the cable cross-section but also the type of thermocouple to be used should be taken into consideration. This product should be used in J-Type thermocouple measurement circuits. For different thermocouple types, the appropriate cable must be selected for the relevant sensor type.

Product Advantages

  • J-Type cable structure suitable for use in thermocouple measurement circuits
  • Two-core construction with nominal cross-section 2x0.75 mm²
  • Combination insulation of silicone and fiberglass
  • Auxiliary steel braid protection against friction and surface mechanical effects
  • Ease of supply of 100 meter rolls for production and maintenance needs
  • Can be cut into different lengths according to application
  • Ease of stocking for serial sensor, machine and control panel connections

Using a compensating cable compatible with the J-Type measurement circuit helps maintain the connection between the sensor and the measuring instrument with the appropriate cable structure.

The actual measurement performance of the system does not depend solely on the cable. The system formed by the sensor, ports, connectors, ambient temperature and measuring instrument should be evaluated together.

Applications

  • J-Type thermocouple sensor connections
  • J-Type Fe-Const temperature measurement circuits
  • Connections between sensor and temperature controller
  • PLC and automation system thermocouple inputs
  • Digital temperature indicators
  • Data-logger and measuring-instrument connections
  • Control panel and field sensor cabling
  • Machine and production line temperature measurements
  • Industrial furnace and heat treatment systems
  • Process temperature measurement applications
  • Maintenance and spare cable stocks
  • Serial sensor and control panel production

Material and Durability Properties

Silicone- and fiberglass-based insulation structure can be preferred in industrial sensor connections where temperature effects are present. However, the exact operating temperature of the cable should not be determined solely by looking at the insulation material.

The temperature limits of the conductor construction, insulation layers, steel braid, terminal, connector and connection points should be evaluated together. For exact operating temperature and thermoelectric tolerance values, the manufacturer's technical documentation should be used as the basis.

The steel braid does not transform the cable into a completely enclosed or leak-proof outer sheath. In environments where there is moisture, liquid, oil, chemicals or dense dust, the product's compliance with environmental conditions should also be checked.

The cable should not be subjected to excessive pulling force, crushing, sharp edges or repeated bending. Steel braid helps with mechanical protection, but does not provide unlimited protection against heavy mechanical loads.

Connection and Usage Notes

In the J-Type thermocouple measurement circuit, the positive and negative conductors must be connected to the corresponding terminals on the sensor and the measuring instrument. Sensor polarity, cable ends and device terminal markings must be checked before installation.

Reverse polarity may cause the temperature change to appear in the wrong direction on the device or to incorrectly interpret the measurement value. The connection polarity from the sensor to the measuring instrument must be maintained.

Compensating cable, thermocouple terminal and connector compatible with J-Type must be used in the J-Type measurement circuit. Standard copper cable or connection materials of different thermocouple types may create inappropriate metal connections in the measurement line.

While preparing the cable end, care should be taken to ensure that the steel braid wires do not come into contact with the measurement cores or device terminals. The shield must be properly removed and the connection area must be isolated in accordance with the application.

Compensating cable should be routed as far as possible from motor supply lines, inverter outputs, contactor lines and high-current power cables.

100-Meter Roll Sales Model

The product is supplied as a single 100-meter roll. Cutting can be done from the roll in lengths required by production, maintenance, panel assembly or field application.

When determining the cutting length, the actual route between the sensor and the measuring instrument, the distance within the panel, the turning points and the mounting allowance required for the terminal connection must be taken into account.

When unrolling, care should be taken to ensure that the cable is not knotted, crushed or bent to a smaller diameter than necessary. The unused section should be stored in a dry, clean area away from the risk of mechanical damage.

100-Meter Rolls of Thermocouple, PT100, and Compensating Cable – Promotional Bulk Purchase

Cables used in production and maintenance processes 100-meter roll options are available for bulk purchase. You can choose the number of cores, nominal cross-sectional area, and insulation construction suitable for your application from the thermocouple, PT100, and compensating cables.

Why Choose a 100-Meter Roll?

  • Unit cost advantage: Roll purchasing facilitates meter-based cost planning in businesses with regular cable consumption.
  • Ease of stock management: The roll format facilitates storage, consumption tracking and production planning.
  • Flexible use: The cable can be cut to the lengths needed in production or in the field.
  • Supply continuity: It helps meet the cable need from stock in regular maintenance and production works.

Which Cable Should I Choose?

  • APPLICATION: The need for thermocouple, PT100 or compensating cable must be determined correctly.
  • Sensor type: A cable compatible with the J, K or other sensor type used in the thermocouple circuit must be selected.
  • Number of cores: Two or three-core cable options should be evaluated depending on the measurement connection.
  • Section: Nominal cross-section appropriate to terminal size, connection distance and mechanical needs should be selected.
  • Insulation: Silicone, fiberglass and steel braid structure should be evaluated together with the environmental conditions.
  • Sales quantity: The estimated consumption of a 100-meter roll in the production and maintenance plan should be calculated.

Bulk Purchasing Advantage and Order Process

This product is aimed at production, maintenance, automation and control panel businesses that need a 100-meter roll of cable. Before ordering, the suitability of the sensor type, number of cores, cross-section, insulation structure and cable construction for the application should be checked.

How to Choose the Correct J-Type Compensating Cable?

When selecting J-Type compensating cable, thermocouple type, measuring instrument input, nominal cross-section, connection distance, insulation structure, mechanical protection need and environmental conditions should be evaluated together.

This product should be used in J-Type Fe-Const thermocouple measurement circuits. For K, T, N, E, R, S or different thermocouple types, a cable compatible with the relevant sensor type must be selected.

When selecting a structure with 2x0.75 mm² cross-section, the compliance of the measuring instrument and connection terminals with this cross-section should be checked. Cable ferrules and other connection elements must be compatible with the core cross-section used.

Related Product Groups

  • 100-meter roll compensating cables
  • J-Type thermocouple cables
  • J-Type compensating cables
  • K-Type compensating cables
  • PT100 sensor cables
  • Silicone insulated cables
  • Fiberglass-insulated cables
  • Steel-braided measurement cables
  • Thermocouple connectors
  • Temperature measurement and control devices

Frequently Asked Questions

Which thermocouple type is this cable suitable for?

This product is prepared for use in temperature measurement circuits with J-Type Fe-Const thermocouple sensors.

What Is a Compensating Cable Used For?

The compensating cable helps maintain the connection between the thermocouple sensor and the measuring or controller in accordance with the relevant thermocouple type.

What does Fe-Const mean?

The expression Fe-Const indicates the thermoelement pair in the J-Type thermocouple circuit. Fe refers to the iron conductor and Const refers to the thermoelement alloy called Constantan.

What Does 2x0.75 mm² Mean?

This statement indicates that the cable consists of two cores and each core has a nominal conductor cross-section of 0.75 mm².

What Is the Supplied Cable Length?

The product is supplied as a single 100-meter roll.

Can the desired length be cut from the roll?

The cable can be used by cutting it from the roll to the lengths required by the application. Cutting and tip preparation should be done with appropriate equipment.

What is the advantage of silicone and fiberglass insulation?

The combination of silicone and fiberglass helps insulate the cable cores and protect the cable body in fixed sensor connections where temperature influences are present.

What does steel braid do?

The steel braid creates an auxiliary layer of mechanical protection around the cable. It helps protect the cable against friction and surface mechanical effects.

Can steel braid be used as an electrical shield?

The main function of the steel braid is mechanical protection. In order to be considered an electrical shield, the electrical continuity of the braid, coverage structure, connection method and manufacturer's technical data must be checked.

Can this product be used as a power cable?

No. This product is used for the connection of thermocouple measurement circuit. It should not be used to power motors, heating elements or other electrical loads.

Who Is a 100-Meter Roll Suitable For?

It is suitable for businesses that produce regular sensors, carry out maintenance-repair work, prepare control panels or need J-Type compensating cables of different lengths.

Technical Document and Application Note

The manufacturer's technical data sheet should be used as the basis for the conductor material of the cable, thermoelectric tolerance class, exact operating temperature, core colors, outer dimension, steel braid material, minimum bending radius and environmental resistance limits.

During product selection and installation, thermocouple type, measuring instrument input, cable cross-section, terminal structure, ambient temperature, humidity, mechanical loads and cabling route should be evaluated together.

★
★
★
★
★
Total 0 Comment made


Thank you for your comment. Your comment will be published after it is done.
Comment on you


Thank you for your question. You will be notified by email once your question has been answered.
Click to Ask a Question
  No questions have been asked for this product yet.
Similar products
Free shipping
%50
J-Type Compensating Cable 2x1.50 mm² – 100-Meter Roll
Free shipping
%50
J-Type (Fe-Const) Thermocouple Cable 2x0.22 mm² – 100-Meter Roll
E-Newsletter
Do you want to be informed first about discounted products and opportunities?
softtr® | Profesyonel E-Ticaret Sistemleri ile hazırlanmıştır.