Whatsapp Destek Hattı
 Endüstriyel Termokupl, PT100 ve Hortum Çözümleri
Select Language
Currency Selection
  • J-Type (Fe-Const) Thermocouple Cable 2x0.22 mm² – 100-Meter Roll
  • J-Type (Fe-Const) Thermocouple Cable 2x0.22 mm² – 100-Meter Roll

ThermoKoTec J-Type (Fe-Const) Thermocouple Cable 2x0.22 mm² – 100-Meter Roll

Product code : J-CCB-2-0,22-Ç-100K
Product Barcode : 791042503566
5.0
★
★
★
★
★
1 evaluation | Question & Answer Add to Favourites
27,605.25 TL   13,802.63 TL  
Free shipping
Color : Black - White

J-Type (Fe-Const) Steel-Braided Thermocouple Cable 2x0.22 mm² – 100-Meter Roll

J-Type (Fe-Const) Thermocouple Cable 2x0.22 mm² is designed for use in the thermoelectric signal connection between the J-Type thermocouple sensor and the temperature measuring instrument or controller. It can be used in temperature controller, indicator, data logger, PLC thermocouple input and control panel connections.

The two-core cable structure has fiberglass insulation layers and a steel braid on the outside. While the fiberglass structure is preferred in fixed industrial connections where temperature effects are present, the steel braid helps protect the cable body against friction and surface mechanical effects.

The product is supplied as a single 100-meter roll and can be cut to the required lengths by businesses engaged in regular sensor production, machine wiring, maintenance and repair work, and control panel assembly.

This product is not a standard power-supply cable. It must be used in a J-Type Fe-Const thermocouple measurement circuit. The sensor type, cable type, connection components, and measuring-instrument input must be mutually compatible, and positive and negative polarity must be maintained throughout the connection.

Fiberglass Insulation and Steel-Braid Construction

The two cores of the cable are separated from each other by fiberglass-based insulation layers. The outer fiberglass braid helps hold the cores together and protect the cable body.

Fiberglass insulation is a preferred structure in thermocouple sensor, machine, oven and control panel connections where temperature effects are present. The exact operating temperature of the cable should not be determined solely by looking at the insulation material.

The temperature limits of the conductor structure, insulation layers, outer braid, terminal, connector and connection points should be evaluated together. For exact operating values, the manufacturer's technical documentation should be used as the basis.

The outer steel braid creates an auxiliary layer of mechanical protection around the cable. It helps protect the cable against friction and light mechanical effects on routes with machine body, panel passage and surface contact.

The main function of the steel braid is mechanical protection. If it is planned to be used as an electrical shield, the electrical continuity of the braid, coverage structure, connection method and device manufacturer's instructions should also be evaluated.

Technical Specifications

  • Product type: Thermocouple cable
  • Thermocouple type: J-Type
  • Thermoelement description: Fe-Const
  • Number of cores: 2 cores
  • Core / cross-sectional area: 2x0.22 mm²
  • Insulation structure: Fiberglass + fiberglass
  • External protection: Steel braid
  • Sales method: 100-meter roll
  • Product code: J-CCB-2-0,22-Ç-100K
  • Product barcode: 791042503566

Fe-Const Thermoelement Structure

The expression Fe-Const indicates the pair of thermoelements used in the J-Type thermocouple circuit. Fe refers to the iron conductor and Const refers to the thermoelement alloy called Constantan.

In J-Type connection, Fe side represents positive polarity and Const side represents negative polarity. During installation, positive-negative terminal markings on the sensor, cable, connector and measuring instrument should be checked.

Product Advantages

  • J-Type Fe-Const cable structure suitable for thermocouple measurement circuits
  • 2x0.22 mm² two-core compact construction
  • Fiberglass insulation for connections where temperature effects are present
  • Auxiliary steel braid protection against friction and surface mechanical effects
  • Ease of supply of 100 meter rolls for production and maintenance needs
  • Can be cut into different lengths as needed
  • Ease of stocking for serial sensor and control panel connections

Using a thermocouple cable compatible with the J-Type sensor helps reduce measurement deviations that may result from improper metal combinations in the measurement line.

The actual measurement performance of the system does not depend solely on the cable. The sensor, cable, ports, connectors, ambient temperature and measuring instrument should be evaluated together.

Applications

  • J-Type thermocouple sensor production and connections
  • J-Type Fe-Const temperature measurement circuits
  • Connections between sensor and temperature controller
  • PLC and automation system thermocouple inputs
  • Digital temperature indicators
  • Data-logger and measuring-instrument connections
  • Control panel and field sensor cabling
  • Machine and production line temperature measurements
  • Industrial furnace and heat treatment applications
  • Process temperature measurement and control systems
  • Maintenance and spare cable stocks
  • Serial sensor and control panel production

Material and Durability Properties

Fiberglass insulation is preferred in industrial thermocouple connections where temperature effects are present. Due to its braided surface structure, it must be protected from sharp bends, crushing and operations that may damage the fiber structure during assembly.

The steel braid does not transform the cable into a completely enclosed or leak-proof outer sheath. In environments where there is moisture, liquid, oil, chemicals or dense dust, the product's compliance with environmental conditions should also be checked.

The cable should not be subjected to excessive pulling force, crushing, sharp metal edges or repeated bending. Steel braid helps with mechanical protection, but does not provide unlimited protection against heavy mechanical loads.

Connection and Usage Notes

In the J-Type thermocouple connection, the positive and negative conductors must be connected to the corresponding terminals on the sensor and measuring instrument. Sensor polarity, cable ends and device terminal markings must be checked before installation.

Reverse polarity may cause the temperature change to appear in the wrong direction on the device or to incorrectly interpret the measurement value. The same polarity pattern must be maintained from the sensor to the measuring instrument.

Thermocouple cable, terminal and thermocouple connector compatible with J-Type must be used in the J-Type measurement circuit. Standard copper cable or connection materials of different thermocouple types may create inappropriate metal connections in the measurement line.

While preparing the cable end, care should be taken to ensure that the steel braid wires do not come into contact with the thermoelement conductors or device terminals. The shield must be properly removed and the connection area must be isolated in accordance with the application.

The thermocouple cable should be carried on a route as separate as possible from motor supply lines, inverter outputs, contactor lines and high-current power cables.

100-Meter Roll Sales Model

The product is supplied as a single 100-meter roll. Cutting can be done from the roll in lengths required by production, maintenance, panel assembly or field application.

When determining the cutting length, the actual route between the sensor and the measuring instrument, the distance within the panel, the turning points and the mounting allowance required for the terminal connection must be taken into account.

When unrolling, care should be taken to ensure that the cable is not knotted, crushed or bent to a smaller diameter than necessary. The unused section should be stored in a dry, clean area away from the risk of mechanical damage.

100-Meter Rolls of Thermocouple, PT100, and Compensating Cable – Promotional Bulk Purchase

Cables used in production and maintenance processes 100-meter roll options are available for bulk purchase. You can choose the number of cores, nominal cross-sectional area, and insulation construction suitable for your application from the thermocouple, PT100, and compensating cables.

Why Choose a 100-Meter Roll?

  • Unit cost advantage: Roll purchasing facilitates meter-based cost planning in businesses with regular cable consumption.
  • Ease of stock management: The roll format facilitates storage, consumption tracking and production planning.
  • Flexible use: The cable can be cut to the lengths needed in production or in the field.
  • Supply continuity: It helps meet the cable need from stock in regular maintenance and production works.

Which Cable Should I Choose?

  • APPLICATION: The need for thermocouple, PT100 or compensating cable must be determined correctly.
  • Sensor type: In the thermocouple circuit, a cable compatible with the J-Type, K-Type or other sensor type used must be selected.
  • Number of cores: Two or three-core cable options should be evaluated depending on the measurement connection.
  • Section: Nominal cross-section appropriate to terminal size, connection distance and mechanical needs should be selected.
  • Insulation: Silicone, fiberglass and steel braid structure should be evaluated together with the environmental conditions.
  • Sales quantity: The estimated consumption of a 100-meter roll in the production and maintenance plan should be calculated.

Bulk Purchasing Advantage and Order Process

This product is aimed at production, maintenance, automation and panel businesses that need a 100-meter roll of cable. Before ordering, the suitability of the sensor type, number of cores, cross-section, insulation structure and cable construction for the application should be checked.

How to Choose the Correct J-Type Thermocouple Cable?

When selecting a J-Type thermocouple cable, sensor type, thermoelement compatibility, nominal cross-section, connection distance, insulation structure, mechanical protection need and characteristics of the measuring instrument input should be evaluated together.

This product should be used in J-Type Fe-Const thermocouple measurement circuits. For K, T, N, E, R, S or different thermocouple types, the thermocouple cable compatible with the relevant sensor type must be selected.

When selecting a 2x0.22 mm² cross-section structure, the suitability of the measuring instrument and connection terminals for the core cross-section used should be checked.

Related Product Groups

  • 100-meter roll thermocouple cables
  • J-Type thermocouple cables
  • K-Type thermocouple cables
  • PT100 sensor cables
  • Compensating cables
  • Fiberglass-insulated cables
  • Steel-braided thermocouple cables
  • Thermocouple connectors
  • Temperature measurement and control devices

Frequently Asked Questions

Which thermocouple type is this cable suitable for?

This product should be used in J-Type Fe-Const thermocouple sensor and measurement circuits.

What does Fe-Const mean?

The expression Fe-Const indicates the thermoelement pair in the J-Type thermocouple circuit. Fe refers to the iron conductor and Const refers to the Constantan thermoelement alloy.

What Does 2x0.22 mm² Mean?

This statement indicates that the cable consists of two cores and each core has a nominal conductor cross-section of 0.22 mm².

What Is the Supplied Cable Length?

The product is supplied as a single 100-meter roll.

Can the desired length be cut from the roll?

The cable can be used by cutting it from the roll to the lengths required by the application. Cutting and tip preparation should be done with appropriate equipment.

What is the advantage of fiberglass insulation?

Fiberglass insulation is preferred in industrial thermocouple connections where temperature effects are present. The exact temperature limits of the cable must be evaluated according to the manufacturer's technical documentation.

What does steel braid do?

The steel braid creates an auxiliary layer of mechanical protection around the cable. It helps protect the cable against friction and surface mechanical effects.

Can steel braid be used as an electrical shield?

The main function of the steel braid is mechanical protection. In order to be considered an electrical shield, the electrical continuity of the braid, coverage structure, connection method and manufacturer's technical data must be checked.

Can this product be used as a power cable?

No. This product is used to transmit a thermocouple measurement signal. It must not be used to power motors, heating elements, or other electrical loads.

Who Is a 100-Meter Roll Suitable For?

It is suitable for businesses that produce regular sensors, carry out maintenance-repair work, prepare control panels or need J-Type thermocouple cables of different lengths.

Technical Document and Application Note

The manufacturer's technical data sheet should be used as the basis for the exact operating temperature of the cable, conductor construction, thermoelement tolerance, core colors, outer dimension, steel braid material, minimum bending radius and environmental resistance limits.

During product selection and installation, thermocouple type, measuring instrument input, cable cross-section, terminal structure, ambient temperature, humidity, mechanical loads and cabling route should be evaluated together.

5.0
★
★
★
★
★
Total 1 Comment made


Thank you for your comment. Your comment will be published after it is done.
Vedat İ.
★
★
★
★
★
tam aradığım, teşekkürler
Comment on you


Thank you for your question. You will be notified by email once your question has been answered.
Click to Ask a Question
  No questions have been asked for this product yet.
Similar products
Free shipping
%50
J-Type Compensating Cable 2x1.50 mm² – 100-Meter Roll
Free shipping
%50
J-Type Compensating Cable 2x0.75 mm² – 100-Meter Roll
E-Newsletter
Do you want to be informed first about discounted products and opportunities?
softtr® | Profesyonel E-Ticaret Sistemleri ile hazırlanmıştır.