Whatsapp Destek Hattı
 Endüstriyel Termokupl, PT100 ve Hortum Çözümleri
Select Language
Currency Selection
  • PT100 Cable 3x0.22, Metal-Braid Shielded, PTFE

ThermoKoTec PT100 Cable 3x0.22, Metal-Braid Shielded, PTFE

Product code : P-SSBS-3-0,22-Ç
Product Barcode : 791042499326
★
★
★
★
★
0 evaluation | Question & Answer Add to Favourites
335.77 TL   285.40 TL  
Wire Legent

PT100 Cable 3x0.22, Metal-Braid Shielded, PTFE

PT100 Cable 3x0.22 with a Metal Braided Shield and PTFE Insulation is an RTD sensor connection and extension cable used in resistance-type temperature measurement circuits, particularly for 3-wire PT100 sensor connections. It transmits the measurement signal from the sensor to a temperature controller, indicator, data logger, PLC system, or control panel.

The three-core cable has a 3x0.22 mm² cross-sectional area and combines PTFE / Teflon core insulation, a metal braided shield, and a transparent PTFE outer sheath. The metal braided shield helps protect the sensor signal line in industrial environments containing sources of electrical noise.

The transparent PTFE outer sheath surrounds the metal braided shield, reducing direct contact of the braid with the external environment. This structure provides additional protection to the cable structure against friction, contamination, moisture and some chemical effects depending on the application. The product is not an energy supply cable, but a sensor cable used to carry the measurement signal of resistance-type temperature sensors.

Metal-Braid Shielded Cable Construction with a PTFE Outer Sheath

The three conductors of the cable are individually insulated with PTFE / Teflon material. The metal braided shield around the cores creates a protective layer that helps reduce the measurement line's exposure to electrical noise sources.

The transparent PTFE outer sheath on the metal braid surrounds the mesh structure and provides additional protection against direct friction, dirt and environmental contact. Thanks to the transparent structure, the physical condition of the metal braid can be checked from the outside.

PTFE / Teflon insulation is preferred in industrial sensor cables due to its temperature resistance, resistance to chemical effects and low-friction surface properties. The exact temperature and chemical resistance limits of the cable must be evaluated according to the manufacturer's technical data sheet.

Technical Specifications

  • Product type: PT100 / RTD sensor connection and extension cable
  • Primary use: 3-wire PT100 sensor connections
  • Compatible sensor group: Resistance-type temperature sensors
  • Example sensor types: PT100, PT1000, and other resistance-type sensors with a suitable connection configuration
  • Cable structure: 3 cores
  • Core / cross-sectional area: 3x0.22 mm²
  • Number of cores: 3 cores
  • Core insulation: PTFE / Teflon
  • Shield/shield: Metal-braid shielded
  • Outer sheath: Transparent PTFE / Teflon
  • External appearance: Metal braid under transparent outer sheath
  • Cable length options: 1, 2, 3, 4 and 5 meters
  • General product barcode: 791042499326

Benefits of a 3-Core RTD Sensor Cable

The three-core cable construction is particularly suitable for 3-wire PT100 measurement circuits. When the measuring instrument supports 3-wire RTD input and the electrical characteristics of the connecting cores are close to each other, it can help compensate for the measurement effect caused by wire resistance.

The 3x0.22 mm² structure provides a compact cable form for transporting the low-level RTD measurement signal between the sensor and the measuring instrument. When selecting the cross-section, connection distance, terminal structure, cabling route and installation area should be evaluated together.

The metal braided shield helps protect the measurement line in environments where there are electrical noise sources such as motor, contactor, inverter, resistance, power cable and control panel. In order for the shield to work effectively, the connection and grounding scheme must be made in accordance with the electrical project of the application.

The combination of PTFE core insulation and the transparent PTFE outer sheath helps separate both the conductors and the metal braided shield from environmental influences. Thus, the braid structure that provides electrical protection and the outer surface protection are combined in a single cable form.

Applications

  • 3-wire PT100 temperature sensor connections
  • Connection structure suitable for PT1000 sensor applications
  • RTD temperature measurement circuits
  • Connections between sensor and temperature controller
  • PLC and automation system RTD inputs
  • Digital temperature indicators
  • Data-logger and measuring-instrument connections
  • Control panel and field sensor connections
  • Industrial temperature measurement systems
  • Machine and production line temperature measurements
  • Process temperature monitoring applications
  • Cabling environments with electromagnetic noise
  • Applications requiring metal-braid shielded sensor cable
  • PTFE sensor connections with outer sheath

Material and Durability Properties

PTFE / Teflon are preferred in industrial sensor applications that require core insulation, temperature and chemical resistance. Its low-friction surface feature can make it easier to pass the cable through appropriate channels and transition points.

The metal braided shield creates a layer of electrical and physical protection around the cable. This structure helps reduce the sensor line's exposure to electromagnetic noise and provides additional mechanical support to the cable body.

The transparent PTFE outer sheath surrounds the metal braid, reducing its exposure to direct friction, contamination and environmental contact. However, the chemical environment, contact time, temperature and mechanical conditions in which the cable will be used must be evaluated specifically for the application.

When determining the actual usage conditions of the cable, the insulation material must not be the only consideration. Ambient temperature, chemical contact, mechanical movement, tensile load, bending conditions, cabling route and connection points should be evaluated together.

Connection and Usage Notes

This product should be considered primarily for 3-wire PT100 connections. The three terminals of the sensor must be connected to the corresponding RTD terminals of the measuring instrument according to the manufacturer's wiring diagram.

On three-wire PT100 sensors, the two terminals on the same side are usually connected to matching terminals on the measuring instrument. However, since core colors may vary depending on the manufacturer, the connection should not be made based on color alone. The sensor diagram and device terminal markings should be checked.

Incorrect core matching, broken connection or short circuit may cause the measurement value to be read incorrectly or the device to display a sensor error. After assembly, connection continuity and terminal tightness should be checked.

The grounding connection of the metal braided shield must be made according to the electrical project of the application and the device manufacturer's instructions. Inappropriate or multiple-point shield connections may create ground loop and unwanted interference problems in some systems.

The sensor cable should be carried on a route as separate as possible from motor supply lines, inverter outputs and high-current power cables. The cable must be protected from sharp edges, crush points and direct flame contact.

Cable Length Options

This product group can be ordered in cable lengths of 1 meter, 2 meters, 3 meters, 4 meters, and 5 meters. Cable length is selected using the Cable Length (K) field. The table below lists the product codes and variant barcodes for the available lengths.

Product Code Cable Type Core / Cross-Section Shield / Shield Insulation Cable Length Variant Barcode
P-SSBS-3-0,22-Ç-1K PT100 / RTD Sensor Cable 3x0.22 mm² Metal-braid shielded PTFE / Teflon 1 Meter 759618174879
P-SSBS-3-0,22-Ç-2K PT100 / RTD Sensor Cable 3x0.22 mm² Metal-braid shielded PTFE / Teflon 2 Meters 791042499333
P-SSBS-3-0,22-Ç-3K PT100 / RTD Sensor Cable 3x0.22 mm² Metal-braid shielded PTFE / Teflon 3 Meters 791042499340
P-SSBS-3-0,22-Ç-4K PT100 / RTD Sensor Cable 3x0.22 mm² Metal-braid shielded PTFE / Teflon 4 Meters 791042499357
P-SSBS-3-0,22-Ç-5K PT100 / RTD Sensor Cable 3x0.22 mm² Metal-braid shielded PTFE / Teflon 5 Meters 791042499364

How to Choose the Correct PT100 / RTD Sensor Cable?

When choosing the PT100 cable, the 2, 3 or 4-wire connection structure of the sensor, number of cores, conductor cross-section, cable length, insulation material, electromagnetic noise level and RTD input type of the measuring instrument should be evaluated together.

This product, with its three-core structure, is primarily suitable for 3-wire PT100 connections. It should be checked that the measuring instrument supports 3-wire RTD input and that the sensor connection ends are compatible with the device terminal structure.

Metal braided shield shielded cable can be preferred in environments where motor, inverter, contactor and power cables are present. The connection method of the shield should be determined by taking into account the grounding scheme of the facility and the recommendations of the device manufacturer.

In applications requiring temperature, chemical contact or external surface protection, PTFE core insulation and PTFE outer sheath may provide advantages. Exact suitability must be determined by comparing the application conditions with the manufacturer's technical data.

Related Product Groups

Frequently Asked Questions

Which sensors are suitable for this cable?

This product is primarily suitable for 3-wire PT100 sensor connections. It can also be used in PT1000 and other resistance-type sensor applications, provided that the connection scheme and measuring instrument input are compatible.

Is This Product a Thermocouple Cable?

No. This product is not thermocouple cable, it is PT100 / RTD sensor cable used for resistance-type temperature sensors.

What is the advantage of the 3-wire PT100 connection?

The 3-wire connection used in a compatible meter can help offset the resistance effect of the cable cores. For this, the sensor connection, core structure and device RTD input must be compatible with each other.

What Does 3x0.22 mm² Mean?

The designation 3x0.22 mm² indicates that the cable consists of three cores and each core has a nominal conductor cross-section of 0.22 mm².

What is the function of the metal braided shield?

The metal braided shield helps reduce the sensor measurement line from being affected by electromagnetic noise. It can be preferred especially in environments where motors, inverters, contactors and power cables are present.

How Should the Metal Braided Shield Be Connected?

Shield connection must be made according to the electrical project of the application and the device manufacturer's instructions. Improper connections or connections made from more than one point may create a ground loop in some systems.

What is the advantage of using PTFE outer sheath and metal braid together?

The metal braided shield helps protect the measurement circuit from electrical noise. The transparent PTFE outer sheath surrounds the braid and provides an additional protective layer against friction, contamination, moisture, and certain application-dependent chemical contact.

What is the advantage of PTFE / Teflon insulation?

PTFE / Teflon insulation is preferred in industrial sensor cables due to its temperature and chemical resistance and low-friction surface properties. Exact usage limits must be determined according to the manufacturer's technical documentation.

Can This Cable Be Used in a 2- or 4-Wire PT100 Connection?

Since this product is three-core, it is designed primarily for 3-wire connections. The connection diagram of the sensor and measuring instrument must be checked before using them in different connection structures.

Can this cable be used for power supply?

No. This product is used for temperature sensor measurement line. It should not be used to power motors, heating elements, or similar electrical loads.

How Is Cable Length Selected?

Select the appropriate 1-, 2-, 3-, 4-, or 5-meter option using the Cable Length field.

Technical Document

The manufacturer's technical data sheet should be used as the basis for the exact operating temperature of the cable, conductor construction, core colors, electrical values, minimum bending radius, metal braid material and chemical resistance limits. During product selection, sensor connection structure, measuring instrument, cable distance, environmental conditions and shield connection method should be evaluated together.

★
★
★
★
★
Total 0 Comment made


Thank you for your comment. Your comment will be published after it is done.
Comment on you


Thank you for your question. You will be notified by email once your question has been answered.
Click to Ask a Question
  No questions have been asked for this product yet.
Similar products
Free shipping
%50
PT100 Cable 3x0.22 mm² – 100-Meter Roll
PT100 Cable 3x0.22 mm² – 100-Meter Roll
31,002.34 TL
15,501.17 TL
Free shipping
%50
PT100 Cable 3x0.34 mm² – 100-Meter Roll
PT100 Cable 3x0.34 mm² – 100-Meter Roll
41,467.03 TL
20,733.51 TL
Free shipping
%50
PT100 Cable 3x0.22 mm² – 100-Meter Roll
PT100 Cable 3x0.22 mm² – 100-Meter Roll
33,576.54 TL
16,788.27 TL
Free shipping
%50
PT100 Cable 2x0.22 mm² with Fiberglass Insulation and Steel Braid – 100-Meter Roll
PT100 Cable 2x0.22 mm² with Fiberglass...
31,450.03 TL
15,725.01 TL
E-Newsletter
Do you want to be informed first about discounted products and opportunities?
softtr® | Profesyonel E-Ticaret Sistemleri ile hazırlanmıştır.