  • K-Type (NiCr-Ni) Teflon Thermocouple Cable 2x0.50 mm²
  • K-Type (NiCr-Ni) Teflon Thermocouple Cable 2x0.50 mm²
  • K-Type (NiCr-Ni) Teflon Thermocouple Cable 2x0.50 mm²

ThermoKoTec K-Type (NiCr-Ni) Teflon Thermocouple Cable 2x0.50 mm²

Product code : K-TT-2-0,5-T
Product Barcode : 791042499029
5.0
★
★
★
★
★
1 evaluation | Question & Answer Add to Favourites
331.26 TL   265.01 TL  
Color : Green - White
Wire Legent

K-Type Teflon Thermocouple Cable 2x0.50 mm²

K-Type (NiCr-Ni) Teflon Thermocouple Cable 2x0.50 mm² is a temperature measurement cable with PFA insulation and a PFA outer sheath for use in K-Type thermocouple measurement circuits. It transmits the thermoelectric signal generated by the sensor to a temperature controller, indicator, data logger, PLC system, or control panel.

The two-core cable has a 2x0.50 mm² cross-sectional area and combines mono/solid thermoelement conductors with PFA fluoropolymer insulation. The PFA core insulation and outer sheath are designed for industrial measurement applications requiring resistance to temperature, moisture, and chemical exposure.

This product is not a standard power cable. It should be used to establish or maintain the measurement circuit with the correct thermoelement structure. For accurate measurement, the cable must be compatible with the K-Type thermocouple and the positive-negative core polarity must be maintained throughout the connection.

PFA-insulated K-Type Thermocouple Cable Structure

The positive and negative thermoelement conductors of the cable are separately insulated with PFA Fluoropolymer. The PFA outer sheath around the cores reduces the direct contact of the insulation layers with the external environment by turning the cable into a single measurement line.

PFA insulation is preferred in industrial temperature measurement cables due to its wide operating temperature range, resistance to chemical effects and low-friction surface properties. The thin and solid conductor structure of the cable helps establish regular connections in fixed installations and applications with limited installation space.

Mono / solid conductors have a single-wire construction. While this structure provides consistent terminal connections in fixed connections, it requires additional consideration of installation conditions in applications with constant movement, intense vibration or frequent bending.

About IEC Color Coding

This K-Type thermocouple cable uses color coding that complies with IEC 60584-3. In a K-Type measurement circuit, the green-insulated NiCr conductor indicates the positive (+)and the white insulated NiAl conductor is negative (-) connection.

The cable's outer sheath is also green. This makes the cable easier to identify as belonging to a K-Type thermocouple circuit during installation, maintenance, and troubleshooting.

Thermocouple cables may have different color code systems such as IEC, ANSI and JIS. For this reason, the same K-Type thermocouple cable can be produced with different core and outer sheath colors depending on the standard used. When choosing a product, not only the thermocouple type but also the color standard used in the current system should be taken into account.

The measurement principle does not change between K-Type cables that use different color standards, provided that their thermoelement alloys are the same. The difference is the colors used to identify the positive and negative conductors. During connection, no action should be taken based solely on core color. The thermocouple type, polarity markings, and device terminal diagram should be checked together.

Technical Specifications

  • Product type: K-Type thermocouple measurement cable
  • Thermocouple type: K-Type (NiCr-Ni)
  • Cable structure: 1 x 2x0.50 mm²
  • Core / cross-sectional area: 2x0.50 mm²
  • Number of cores: 2 cores
  • Conductor structure: Mono / Solid
  • Positive conductor (+): NiCr, green insulation
  • Negative conductor (-): NiAl, white insulation
  • Core colors: Green and white
  • Conductor insulation: PFA Fluoropolymer
  • Outer sheath: PFA Fluoropolymer
  • Outer sheath color: Green
  • Color code standard: IEC 60584-3
  • Continuous operating temperature: -90°C / +260°C
  • Short-term operating temperature: +280°C
  • Operating voltage: 300/500V
  • Test voltage: 2.00kV
  • Cable length options: 1, 2, 3, 4 and 5 meters
  • General product barcode: 791042499029

Benefits of the K-Type Thermocouple Cable

K-Type thermocouple cable enables the measurement line between the sensor and the measuring instrument to be established with the K-Type thermoelement structure. Choosing the cable type compatible with the sensor and device helps reduce measurement deviations that may arise from different metal combinations at the connection points.

The 2x0.50 mm² construction offers a balance between terminal connectivity and mechanical strength in industrial temperature measurement circuits. When selecting the cross-sectional area, the wiring distance, terminal size, installation space, and thermocouple connector should be considered together.

PFA insulation and outer sheath provide advantages in applications requiring resistance to high and low ambient temperatures and chemical effects. The low-friction outer surface can make it easier to route the cable through appropriate channels and transition points.

The green and white cores are easy to distinguish, facilitating polarity checks during connection. The green outer sheath makes it easier to identify the cable as part of a K-Type thermocouple circuit in control-panel and field wiring.

Applications

  • K-Type thermocouple sensor connections
  • Thermocouple measurement circuits
  • Connections between sensor and temperature controller
  • PLC and automation system thermocouple inputs
  • Digital temperature indicators
  • Data-logger and measuring-instrument connections
  • Industrial temperature measurement and control systems
  • Petrochemical plants
  • Pharmaceutical industry
  • Food processing plants
  • Agro-industrial applications
  • Public and industrial facilities
  • Machine and production line temperature measurements
  • Process temperature monitoring applications

Material and Durability Properties

PFA Fluoropolymer core insulation and outer sheath structure are suitable for industrial measurement applications that require temperature and chemical resistance. According to the manufacturer's technical data, the cable is suitable for continuous operation between -90°C and +260°C and for short periods at +280°C.

PFA outer sheath helps protect the cable structure in working environments requiring moisture, chemical contact and low-friction surfaces. In applications with UV exposure, usage conditions and exposure duration should be evaluated by taking into account the manufacturer's technical documentation.

When determining the actual operating conditions of the cable, the temperature value of the insulation material must not be the only consideration. Ambient temperature, mechanical movement, vibration, chemical contact, wiring route, connection points and the terminal or connector used should be evaluated together.

Connection and Usage Notes

In the K-Type thermocouple circuit, the positive and negative conductors must be connected to the correct terminals. In this product green core indicates the positive (+)and the white core indicates the negative (-) connection.

Reverse polarity may cause the measurement value to change in the wrong direction or the indicator to decrease as the temperature rises. The positive and negative terminal markings on the controller, indicator or PLC should be checked before connection.

When making the connection, use a cable, terminal, and thermocouple connector compatible with K-Type. The use of standard copper cable, cable of a different thermocouple type or unsuitable connection elements may cause deviation in the measurement circuit.

Due to its mono/solid conductor structure, the cable should not be stressed on routes with constant movement or frequent bending. The cable must be protected from sharp edges, crush points and direct flame contact.

Thermocouple cable should be carried on a route as separate as possible from power cables, motor supply lines and inverter outputs in facilities where electromagnetic noise sources are present.

Cable Length Options

This product group can be ordered in cable lengths of 1 meter, 2 meters, 3 meters, 4 meters, and 5 meters. Cable length is selected using the Cable Length (K) field. The table below lists the product codes and variant barcodes for the available lengths.

Product Code Thermocouple Type Core / Cross-Section Conductor Structure Insulation Cable Length Variant Barcode
K-TT-2-0,5-T-1K K-Type (NiCr-Ni) 2x0.50 mm² Mono / Solid PFA 1 Meter 759618150750
K-TT-2-0,5-T-2K K-Type (NiCr-Ni) 2x0.50 mm² Mono / Solid PFA 2 Meters 791042499036
K-TT-2-0,5-T-3K K-Type (NiCr-Ni) 2x0.50 mm² Mono / Solid PFA 3 Meters 791042499043
K-TT-2-0,5-T-4K K-Type (NiCr-Ni) 2x0.50 mm² Mono / Solid PFA 4 Meters 791042499050
K-TT-2-0,5-T-5K K-Type (NiCr-Ni) 2x0.50 mm² Mono / Solid PFA 5 Meters 791042499067

How to Choose the Correct K-Type Thermocouple Cable?

When choosing a K-Type thermocouple cable, sensor type, thermoelement alloy, conductor cross-section, conductor structure, insulation material, cable length, color code standard, ambient temperature and the device to be connected should be evaluated together.

This product is suitable for K-Type (NiCr-Ni) thermocouple measurement circuits. For J, T, N, R, S or different types of thermocouple sensors, a thermocouple cable suitable for the relevant type must be used.

Mono/solid conductor structure may be preferred in fixed connections. In applications involving continuous movement, intense vibration or repetitive bending, cable options with flexible conductors suitable for the application should be evaluated.

Related Product Groups

Frequently Asked Questions

Which thermocouple type is this cable suitable for?

This product is suitable for K-Type (NiCr-Ni) thermocouple sensors and measurement circuits.

Is This Product an Extension Cable?

This product is a thermocouple measurement cable with K-Type thermoelement alloys. It can be used to establish or extend the K-Type measurement line between the sensor and the measuring instrument.

What is the insulation material of this cable?

The insulation of positive and negative conductors and the outer sheath of the cable are PFA Fluoropolymer structure.

What Does 2x0.50 mm² Mean?

The expression 2x0.50 mm² indicates that the cable consists of two cores and each core is in cross-section class 0.50 mm².

What does mono/solid conductor mean?

Mono/solid conductor indicates that each core consists of a single wire. It provides consistent terminal connections in fixed installations. However, in applications with constant movement and frequent bending, installation conditions should be evaluated separately.

What do green and white cores mean?

According to IEC 60584-3 color coding, green insulated NiCr core indicates positive (+) connection and white insulated NiAl core indicates negative (-) connection.

Does Every K-Type Thermocouple Cable Use Green and White Cores?

No. Different color code standards can be used for thermocouple cables, such as IEC, ANSI and JIS. For this reason, the same K-Type cable can be produced with different core and outer sheath colors in different standards.

In what temperature range can this cable be used?

According to the manufacturer's technical data, the continuous operating temperature of the cable is between -90°C and +260°C. Short-term operating temperature is stated as +280°C.

Can this cable be used for power supply?

This product is a thermocouple measurement cable. It should not be used to power a motor or heating element or similar power loads.

How Is Cable Length Selected?

Select the appropriate 1-, 2-, 3-, 4-, or 5-meter option using the Cable Length field.

Technical Document

The manufacturer's technical data sheet includes technical information such as IEC 60584-3 standard, PFA insulation structure, conductor alloys, color coding, operating temperatures, operating voltage and test voltage. During product selection and installation, the information on the product page and the manufacturer's technical documentation should be used as the basis.

5.0
★
★
★
★
★
Total 1 Comment made


Thank you for your comment. Your comment will be published after it is done.
Caglar E.
★
★
★
★
★
Comment on you


Thank you for your question. You will be notified by email once your question has been answered.
Click to Ask a Question
  No questions have been asked for this product yet.
Similar products
New Product
%20
K-Type OMEGA Fiberglass-Braid Insulated Thermocouple Cable 24 AWG
%20
K-Type Ultra-Thin Fiberglass-Insulated Thermocouple Cable 2x0.10 mm
Free shipping
%50
K-Type Compensating Cable 2x1.50 mm² – 100-Meter Roll
Free shipping
%50
K-Type Compensating Cable 2x0.75 mm² – 100-Meter Roll
Free shipping
%50
K-Type (NiCr-Ni) Steel-Braided Thermocouple Cable 2x0.22 mm² – 100-Meter Roll
E-Newsletter
Do you want to be informed first about discounted products and opportunities?
softtr® | Profesyonel E-Ticaret Sistemleri ile hazırlanmıştır.