Whatsapp Destek Hattı
 Endüstriyel Termokupl, PT100 ve Hortum Çözümleri
Select Language
Currency Selection
  • K-Type (NiCr-Ni) JIS Teflon Thermocouple Cable 2x0.50 mm²

ThermoKoTec K-Type (NiCr-Ni) JIS Teflon Thermocouple Cable 2x0.50 mm²

Product code : K-TT-JIS-2-0,5-T
Product Barcode : 791042501326
★
★
★
★
★
0 evaluation | Question & Answer Add to Favourites
330.54 TL   231.38 TL  
Color : Blue - Red - White
Wire Legent

K-Type JIS Teflon Thermocouple Cable 2x0.50 mm²

K-Type JIS Teflon Thermocouple Cable 2x0.50 mm² is a Teflon-insulated temperature measurement cable used in K-Type NiCr-Ni thermocouple measurement circuits. It is used to transmit the thermoelectric signal generated by the thermocouple sensor to the temperature controller, indicator, data logger, PLC system or control panel.

The two-core cable has a cross-sectional area of 2x0.50 mm² and combines mono/solid thermoelement conductors, Teflon insulation and JIS color coding. 0.50 mm² conductor cross-section offers a balanced structure between mechanical strength and practical installation in panel connections and field applications.

This product is not a standard power cable. It should be used to establish or maintain the measurement circuit with the appropriate thermoelement structure. For accurate measurement, the cable must be compatible with the K-Type thermocouple and the positive-negative core polarity must be maintained throughout the connection.

Teflon-Insulated Mono/Solid Cable Construction

The positive and negative thermoelement conductors of the cable are separately insulated with Teflon material. The insulating layer helps electrically protect the measurement line by preventing the cores from touching each other or surrounding conductive surfaces.

Teflon insulation is preferred in industrial measurement applications requiring resistance to heat and chemical contact, as well as a low-friction surface. The exact fluoropolymer type, operating temperature, and chemical compatibility of the insulation must be evaluated according to the manufacturer's technical data sheet.

In a mono/solid conductor construction, each core consists of a single wire. This structure provides consistent terminal connections in fixed installations and panel connections. In applications involving continuous movement, intense vibration or repeated bending, the mechanical suitability of the cable must be evaluated separately.

About JIS Color Coding

This K-Type thermocouple cable uses JIS color coding. The red-insulated core indicates the positive (+)and the white-insulated core indicates the negative (-) connection.

The cable has a blue outer sheath. The blue outer sheath and red and white cores make it easier to identify the cable as part of a K-Type JIS thermocouple circuit during installation, maintenance, and troubleshooting.

Different color code systems can be used on thermocouple cables, such as JIS, IEC and ANSI. Therefore, the same K-Type thermocouple cable can be produced with different core and outer sheath colors depending on the standard used. When choosing a product, not only the thermocouple type but also the color code standard used in the current system should be taken into account.

The measurement principle does not change between a JIS-color-coded K-Type thermocouple cable and K-Type cables using other color standards, provided that their thermoelement construction is the same. The principal difference is the colors used to identify the positive and negative conductors.

When connecting to an installation or measuring instrument with a different color standard, the process should not be based solely on the core color. Thermocouple type, polarity markings and device connection diagram should be checked together.

Technical Specifications

  • Product type: K-Type thermocouple measurement cable
  • Thermocouple type: K-Type JIS
  • Thermoelement description: NiCr-Ni
  • Cable structure: 1 x 2x0.50 mm²
  • Core / cross-sectional area: 2x0.50 mm²
  • Number of cores: 2 cores
  • Conductor structure: Mono / Solid
  • Positive core (+): Red insulation
  • Negative core (-): White insulation
  • Internal core colors: Red and white
  • Insulation: Teflon
  • Outer sheath color: Blue
  • Color code standard: JIS
  • Cable length options: 1, 2, 3, 4 and 5 meters
  • General product barcode: 791042501326

Benefits of the K-Type JIS Thermocouple Cable

K-Type thermocouple cable enables the line between the sensor and the measuring instrument to be established with the K-Type thermoelement structure. Choosing the cable compatible with the sensor type helps reduce measurement deviations that may arise from unsuitable connection materials.

The 2x0.50 mm² construction offers a balance between mechanical strength and practical installation for control-panel connections and field applications. When selecting the cable cross-sectional area, the connection distance, terminal size, installation space, and thermocouple connector should be considered together.

Offering a tougher structure than cables with thinner cross-sections, it can help the cable to be used in a more controlled manner in internal panel transitions, fixed sensor lines and terminal connections.

Teflon insulation is beneficial in applications requiring resistance to heat and chemical contact, as well as a low-friction surface. It can make the cable easier to route through suitable cable ducts, control-panel openings, and device connection points.

Easy separation of red and white wires makes polarity control easier during connection. The blue outer sheath helps to identify the cable faster in facilities using the JIS color standard.

Applications

  • K-Type thermocouple sensor connections
  • K-Type NiCr-Ni thermocouple measurement circuits
  • Connections between sensor and temperature controller
  • PLC and automation system thermocouple inputs
  • Digital temperature indicators
  • Data-logger and measuring-instrument connections
  • Industrial temperature measurement and control systems
  • Control panel and field sensor connections
  • Machine and production line temperature measurements
  • Process temperature monitoring applications
  • Thermocouple signal transmission lines
  • Facilities using JIS color standard
  • Machinery and control systems built to the Japanese standard

Material and Durability Properties

Teflon insulation is preferred in industrial temperature measurement applications requiring temperature and chemical resistance. Its low-friction surface can make the cable easier to route through suitable ducts and passage points.

2x0.50 mm² cross-section provides a tougher physical structure than thin-section cables. However, in applications with tensile loads, crushing, sharp bending or continuous movement, the mechanical suitability of the cable should be evaluated separately.

Its mono/solid conductor structure ensures regular use in fixed installations and panel connections. In applications where the cable is constantly moving, exposed to vibration or frequently bent, alternatives with flexible conductors should be considered.

Insulation material must not be the only consideration when determining the cable's actual operating conditions. Ambient temperature, chemical contact, mechanical movement, minimum bending requirements, connection distance, wiring route, and the terminal or connector used must be evaluated together.

Connection and Usage Notes

In a K-Type thermocouple circuit, the positive and negative conductors must be connected to the correct terminals. Under the JIS color code, the red core indicates the positive (+)and the white core indicates the negative (-) connection.

Reversed polarity may cause the measured value to move in the wrong direction as the temperature changes or cause the device to display an incorrect value. The positive and negative terminal markings on the controller, indicator, or PLC must be checked before connection.

When making the connection, use a cable, terminal, and thermocouple connector compatible with K-Type. The use of a standard copper connection cable, a cable for a different thermocouple type or unsuitable connection elements may cause measurement deviation.

If a connection is to be made to a system with an IEC or ANSI color code, the cores should not be matched based on color alone. Since positive and negative core colors may vary in different standards, the connection must be made according to the terminal markings and device diagram.

Due to its mono/solid conductor structure, the cable should not be stressed on routes with constant movement or frequent bending. The cable must be protected from sharp edges, crush points and direct flame contact.

The thermocouple cable must be routed as far as possible from motor supply circuits, inverter outputs, and high-current power cables. Suitable shielded cable and installation methods should be considered in applications with high levels of electrical noise.

Cable Length Options

This product group can be ordered in cable lengths of 1 meter, 2 meters, 3 meters, 4 meters, and 5 meters. Cable length is selected using the Cable Length (K) field. The table below lists the product codes and variant barcodes for the available lengths.

Product Code Thermocouple Type Core / Cross-Section Conductor Structure Insulation Cable Length Variant Barcode
K-TT-JIS-2-0,5-T-1K K-Type JIS (NiCr-Ni) 2x0.50 mm² Mono / Solid Teflon 1 Meter 759618174961
K-TT-JIS-2-0,5-T-2K K-Type JIS (NiCr-Ni) 2x0.50 mm² Mono / Solid Teflon 2 Meters 791042501333
K-TT-JIS-2-0,5-T-3K K-Type JIS (NiCr-Ni) 2x0.50 mm² Mono / Solid Teflon 3 Meters 791042501340
K-TT-JIS-2-0,5-T-4K K-Type JIS (NiCr-Ni) 2x0.50 mm² Mono / Solid Teflon 4 Meters 791042501357
K-TT-JIS-2-0,5-T-5K K-Type JIS (NiCr-Ni) 2x0.50 mm² Mono / Solid Teflon 5 Meters 791042501364

How to Choose the Correct K-Type JIS Thermocouple Cable?

When choosing a K-Type JIS thermocouple cable, sensor type, thermoelement compatibility, color code standard, conductor cross-section, conductor structure, insulation material, cable length and measuring instrument to be used should be evaluated together.

This product is suitable for K-Type NiCr-Ni thermocouple measurement circuits. For J, T, N, E, R, S or different types of thermocouple sensors, a measurement cable suitable for the relevant thermocouple type must be used.

2x0.50 mm² mono / solid structure can be preferred for fixed panel and field connections. In applications involving continuous movement, intense vibration or repetitive bending, cable options with flexible conductors should be considered.

If the existing system is prepared according to the JIS color code, using the same standard facilitates cable tracking during installation, maintenance and fault detection. If a connection is to be made to a system with a different color standard, matching should be done not only on color but also on polarity and terminal diagram.

Related Product Groups

Frequently Asked Questions

Which thermocouple type is this cable suitable for?

This product is suitable for K-Type NiCr-Ni thermocouple sensors and measurement circuits.

What Does JIS Color Coding Mean?

JIS color coding is a Japanese color coding system that allows thermocouple type and positive and negative conductors to be identified with specific colors. In this product, the positive core is red and the negative core is white.

Is the JIS color-coded K-Type cable different in terms of measurement?

No. As long as the thermoelement construction is K-Type NiCr-Ni, the measurement principle is the same. The main difference is the standard used to define the core and outer-sheath colors.

What is the color scheme of this product?

The outer sheath of the product is blue. The positive core has red insulation and the negative core has white insulation.

What Does 2x0.50 mm² Mean?

The expression 2x0.50 mm² indicates that the cable consists of two cores and each core is in cross-section class 0.50 mm².

What does mono/solid conductor mean?

A mono/solid conductor means that each core consists of a single wire. It provides a consistent terminal connection in fixed installations; however, the operating conditions must be evaluated separately for applications involving continuous movement and frequent bending.

What is the advantage of Teflon insulation?

Teflon insulation is preferred in industrial temperature measurement cables due to its temperature and chemical resistance and low-friction surface properties. The exact operating conditions must be determined according to the manufacturer's technical documentation.

Can this cable be used for power supply?

No. This product is used to transmit a thermocouple measurement signal. It must not be used to power motors, heating elements, or similar electrical loads.

How Is Cable Length Selected?

Select the appropriate 1-, 2-, 3-, 4-, or 5-meter option using the Cable Length field.

Technical Document

The manufacturer's technical data sheet must be used as the basis for the cable's exact operating temperature, specific type of Teflon insulation, conductor alloy, conductor tolerance, outer dimensions, operating voltage, and other electrical properties. The thermocouple type, JIS color standard, connection distance, mechanical conditions, and device-terminal configuration must be evaluated together during product selection and installation.

★
★
★
★
★
Total 0 Comment made


Thank you for your comment. Your comment will be published after it is done.
Comment on you


Thank you for your question. You will be notified by email once your question has been answered.
Click to Ask a Question
  No questions have been asked for this product yet.
Similar products
New Product
%20
K-Type OMEGA Fiberglass-Braid Insulated Thermocouple Cable 24 AWG
%20
K-Type Ultra-Thin Fiberglass-Insulated Thermocouple Cable 2x0.10 mm
Free shipping
%50
K-Type Compensating Cable 2x1.50 mm² – 100-Meter Roll
Free shipping
%50
K-Type Compensating Cable 2x0.75 mm² – 100-Meter Roll
Free shipping
%50
K-Type (NiCr-Ni) Steel-Braided Thermocouple Cable 2x0.22 mm² – 100-Meter Roll
E-Newsletter
Do you want to be informed first about discounted products and opportunities?
softtr® | Profesyonel E-Ticaret Sistemleri ile hazırlanmıştır.